On this page
Overview
The Qolsys IQ Pro panel targets pro/commercial-grade installs with expanded I/O, PowerG, and Alarm.com integration compared to residential IQ4 SKUs.
The panel is the brain of the intrusion system: it supervises wired and wireless zones, drives bell/siren outputs, manages automation on supported models, and reports to Alarm.com when a compatible communicator is installed. Installers program zones, user codes, and dialer options with installer menu / pairing wizard (varies by IQ Panel 4, 5, Hub); end users arm/disarm from IQ Remote, keyfobs, or Alarm.com app.
At a Glance
| Specification | Details |
|---|---|
| Role | Pro-grade IQ panel platform |
| Wireless | PowerG sensor ecosystem |
| Use | Larger installs needing pro panel features |
What This Panel Does Well
Coordinates intrusion zones, automation, user codes, and central station reporting when cell and monitoring are configured.
Before You Service or Replace One
- Exact panel model — IQ Panel 4 vs IQ5 vs IQ Pro vs IQ Hub — firmware and modules differ.
- Encryption — PowerG vs legacy card vs hardwire module sensors in the field.
- Cell module SKU — Built-in cellular vs Wi-Fi path per panel SKU and Alarm.com plan.
- Installer code — required for zone changes; document before service.
- Alarm.com dealer — account status, plan, and remote programming access.
Official Sources
- Qolsys product page
- IQ PRO Install Manual 29011132R007 WEB
- IQ Pro User Manual
- IQ Pro Flyer
- IQ Pro DNA Chart v8
- IQ Pro Flyer Spec New
Use official Qolsys install PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.
Installation Notes
Follow IQ Pro installation and programming guide and the official resource links in this product folder for mounting, wiring, and enrollment.
Pre-install checklist
- Confirm panel model (IQ Panel 4/5/Pro/Hub) and encryption requirements.
- Verify dealer cell account and module SKU before cell install.
- Document installer code and existing zone map for takeover jobs.
- Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
- Have listed batteries and tools for sensor mounts before enrollment.
Typical install sequence
- Mount and power panel; apply firmware updates per dealer bulletin.
- Install cell module and run communication test / Alarm.com activation.
- Enroll wireless sensors via installer Learn mode; label zones.
- Include Z-Wave devices after excluding from any prior hub.
- Install IQ Card for legacy sensors or optimize PowerG placement before fringe wireless devices.
- Run walk test, user code training, and central station test if monitored.
Power and connectivity reference
| Product type | Power | Network / RF |
|---|---|---|
| IQ Panel 4/5/Pro/Hub panel | AC + backup battery | PowerG sensors; IQ Cards; Z-Wave automation |
| Wireless sensor | Battery per SKU | PowerG encrypted; IQ Card 319/345 legacy |
| Cell module | Panel-powered | LTE to dealer / Alarm.com |
| IQ Remote keypad | PowerG link | IQ Panel host |
| Z-Wave module | Mains or battery per device | Z-Wave to panel |
Source: IQ Pro installation and programming guide (Qolsys official documentation).
FAQs
Which Qolsys IQ panel do I have?
Check label and installer paperwork — **IQ Panel 4, IQ Panel 5, IQ Pro, and IQ Hub use different modules, firmware, and screen layouts. IQ Panel 4/5 support PowerG; legacy sensors need matching IQ Card sensors.
Why does my panel show cell failure?
Usually inactive SIM, wrong module SKU, weak RSSI, or antenna fault — run installer cell test and verify Alarm.com/dealer activation.
Can I add sensors myself?
Wireless enrollment requires installer code on the panel for new zones — end users typically cannot add sensors without installer access.
Standard vs encrypted sensors?
PowerG S-Line sensors require IQ Panel or IQ Hub hosts. Legacy 319/345 MHz sensors require the matching IQ Card installed.
Where is official documentation?
- Qolsys product page
- IQ PRO Install Manual 29011132R007 WEB
- IQ Pro User Manual
- IQ Pro Flyer
- IQ Pro DNA Chart v8
- IQ Pro Flyer Spec New
Primary reference: IQ Pro installation and programming guide
How do I test after installation?
Use panel walk test, zone status, and (if monitored) central station test per dealer procedure.
Can I mix PowerG and 319/345 MHz legacy sensors?
PowerG needs IQ Panel/H hub; 319/345 needs IQ Card 319/345 installed transceiver hardware — they do not enroll on the standard 345 MHz receiver alone.
Which Qolsys IQ panel do I have?
Check label and installer paperwork — **IQ Panel 4, IQ Panel 5, IQ Pro, and IQ Hub use different modules, firmware, and screen layouts. IQ Panel 4/5 support PowerG; legacy sensors need matching IQ Card sensors.
Why does my panel show cell failure?
Usually inactive SIM, wrong module SKU, weak RSSI, or antenna fault — run installer cell test and verify Alarm.com/dealer activation.
Can I add sensors myself?
Wireless enrollment requires installer code on the panel for new zones — end users typically cannot add sensors without installer access.
Standard vs encrypted sensors?
PowerG S-Line sensors require IQ Panel or IQ Hub hosts. Legacy 319/345 MHz sensors require the matching IQ Card installed.
Where is official documentation?
- Qolsys product page
- IQ PRO Install Manual 29011132R007 WEB
- IQ Pro User Manual
- IQ Pro Flyer
- IQ Pro DNA Chart v8
- IQ Pro Flyer Spec New
Primary reference: IQ Pro installation and programming guide
How do I test after installation?
Use panel walk test, zone status, and (if monitored) central station test per dealer procedure.
Can I mix PowerG and 319/345 MHz legacy sensors?
PowerG needs IQ Panel/H hub; 319/345 needs IQ Card 319/345 installed transceiver hardware — they do not enroll on the standard 345 MHz receiver alone.