Overview
The PC4664 is a MAXSYS graphic annunciator kit that displays zone status, troubles, device operation, and system events at a glance on a wall-mounted graphic layout. The PC4664 shows up to 64 events on a 11" × 17" (279 × 432 mm) display. It connects to PC4010/PC4020 MAXSYS panels over Combus and is programmed from an enrolled LCD keypad or DLS downloading software—same workflow as the rest of the MAXSYS system.
The companion PC4632 model offers 32 events on a smaller display; setup and programming are similar (see shared install manual).
At a Glance
| Specification | PC4664 |
|---|---|
| Display capacity | Up to 64 events |
| Display size | 11" × 17" (279 × 432 mm) |
| Host panel | PC4010 / PC4020 MAXSYS |
| Bus connection | Combus (4-wire) |
| Programming | LCD4500/LCD4501 keypad or DLS download |
| Output driver | Enrolled as PC4216 low-power output module |
| Indicators | Zone open/close, troubles, device operation, system status |
| Typical use | manufacturing plants, warehouses, large offices, and residential apartment buildings |
Before You Install One
Complete these PC4020 steps first:
- Plan and wire the PC4020 system (install manual).
- Install panel, power, and at least one LCD keypad for programming.
- Install and enroll zone expander modules (PC4108A, PC4116).
- Install and enroll detectors in final locations—makes annunciator layout planning accurate.
Then plan annunciator layout artwork (supplied templates or custom), Combus homerun, tamper, and LED matrix wiring.
Official Sources
- Product page: DSC MAXSYS 64 Point Graphic Annunciators (ID 34)
- PC4632/PC4664 Installation Manual v1.0 (English NA) — DSC official documentation
- MAXSYS engineer specification sheet — system context
Error Codes
The PC4664 does not maintain a separate end-user trouble code table—it reflects PC4020 system troubles and Combus module faults on its graphic display and follows host panel trouble logic.
What the Annunciator Shows
| Indication | Meaning |
|---|---|
| Zone open/close icons | Real-time zone state per programmed layout |
| Trouble indicators | Host panel troubles (battery, AC, FTC, zone fault, etc.) |
| Device operation | Programmed PGM/output or access events |
| Blank / frozen display | Combus comms loss, power loss, or PC4216 enrollment fault |
Host Panel Troubles Affecting Display
When the graphic display stops updating, check **[*, 2]** on the host PC4020 keypad for:
| Host trouble | Effect on annunciator |
|---|---|
| Aux Supply Troub | PC4216 output overload—display may dim or fail |
| Module E fault on PC4216 slot | Communications lost—display frozen |
| Module LV fault | Insufficient Combus power—intermittent updates |
| Module T tamper | Annunciator enclosure tamper |
Run host diagnostics [04] to identify the PC4216 module number assigned to the annunciator.
Source: PC4632/PC4664 Installation Manual; PC4020 v3.5 Installation Manual §16.
| Code | Meaning | Suggested Fix |
|---|---|---|
| Indication | Meaning | |
| Zone open/close icons | Real-time zone state per programmed layout | |
| Trouble indicators | Host panel troubles (battery, AC, FTC, zone fault, etc.) | |
| Device operation | Programmed PGM/output or access events | |
| Blank / frozen display | Combus comms loss, power loss, or PC4216 enrollment fault | |
| Host trouble | Effect on annunciator | |
| Aux Supply Troub | PC4216 output overload—display may dim or fail | |
| Module E fault on PC4216 slot | Communications lost—display frozen | |
| Module LV fault | Insufficient Combus power—intermittent updates | |
| Module T tamper | Annunciator enclosure tamper |