Qolsys IQ Heat 135/200 – IQ Installation Notes

PowerG smoke or CO detector — life-safety wireless device for IQ systems (IQ Smoke, IQ Carbon, IQ Heat). Life-safety devices have stricter placement and testing requirements than burglary sensors. Follow NFPA/local ...

Overview

PowerG smoke or CO detector — life-safety wireless device for IQ systems (IQ Smoke, IQ Carbon, IQ Heat).

Life-safety devices have stricter placement and testing requirements than burglary sensors. Follow NFPA/local code, use professional monitoring where required, and never substitute takeover modules for fire or CO hardwire.

At a Glance

SpecificationDetails
DetectionSmoke, CO, or heat — SKU specific
WirelessPowerG encrypted
Life safetyFollow code; professional monitoring recommended

What This Device Does Well

Provides reliable supervised status at the panel and Alarm.com when installed, enrolled, and range-tested correctly.

Before You Service or Replace One

  • Device age — smoke/CO sensors expire; replace per label date.
  • Zone type — fire vs burglary programming differs; do not bypass without authority.
  • FireFighter placement — acoustic path to standalone smoke alarms.
  • Monitoring — central station fire test procedures for monitored accounts.

Official Sources

Use official Qolsys install PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.

Installation Notes

Follow IQ smoke/CO install guide and the official resource links in this product folder for mounting, wiring, and enrollment.

Pre-install checklist

  • Confirm panel model (IQ Panel 4/5/Pro/Hub) and encryption requirements.
  • Verify dealer cell account and module SKU before cell install.
  • Document installer code and existing zone map for takeover jobs.
  • Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
  • Have listed batteries and tools for sensor mounts before enrollment.

Typical install sequence

  1. Mount and power panel; apply firmware updates per dealer bulletin.
  2. Install cell module and run communication test / Alarm.com activation.
  3. Enroll wireless sensors via installer Learn mode; label zones.
  4. Include Z-Wave devices after excluding from any prior hub.
  5. Install IQ Card for legacy sensors or optimize PowerG placement before fringe wireless devices.
  6. Run walk test, user code training, and central station test if monitored.

Power and connectivity reference

Product typePowerNetwork / RF
IQ Panel 4/5/Pro/Hub panelAC + backup batteryPowerG sensors; IQ Cards; Z-Wave automation
Wireless sensorBattery per SKUPowerG encrypted; IQ Card 319/345 legacy
Cell modulePanel-poweredLTE to dealer / Alarm.com
IQ Remote keypadPowerG linkIQ Panel host
Z-Wave moduleMains or battery per deviceZ-Wave to panel

Source: IQ smoke/CO install guide (Qolsys official documentation).