IQ Card radio module — adds legacy sensor frequency support (319.5 MHz, 345 MHz, 433 MHz), PowerG, Zigbee, or Ethernet to compatible IQ panels.
On IQ Panel systems, wireless devices are supervised zones on the panel — tamper, low battery, and missing signals appear as trouble conditions that may block arming depending on panel programming.
At a Glance
| Specification | Details |
|---|---|
| Role | Panel radio/card expansion |
| SKUs | IQ Card 319, 345, 433, PG, Zigbee, Ethernet |
| Install | Internal card slot — panel must support card type |
What This Device Does Well
Provides reliable supervised status at the panel and Alarm.com when installed, enrolled, and range-tested correctly.
Before You Service or Replace One
- Sensor SKU — PowerG S-Line vs IQ Card legacy vs hardwire module.
- Panel online — resolve panel AC/comms trouble before blaming sensor.
- Range — sensor placement or add IQ Remote as repeater path where supported for distant zones.
- Battery type — use listed cell; replace all batteries in multi-cell devices.
- Tamper — cover fully closed before declaring hardware fault.
Official Sources
Use official Qolsys install PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.
Installation Notes
Follow IQ Card quick guide for your frequency and the official resource links in this product folder for mounting, wiring, and enrollment.
Pre-install checklist
- Confirm panel model (IQ Panel 4/5/Pro/Hub) and encryption requirements.
- Verify dealer cell account and module SKU before cell install.
- Document installer code and existing zone map for takeover jobs.
- Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
- Have listed batteries and tools for sensor mounts before enrollment.
Typical install sequence
- Mount and power panel; apply firmware updates per dealer bulletin.
- Install cell module and run communication test / Alarm.com activation.
- Enroll wireless sensors via installer Learn mode; label zones.
- Include Z-Wave devices after excluding from any prior hub.
- Install IQ Card for legacy sensors or optimize PowerG placement before fringe wireless devices.
- Run walk test, user code training, and central station test if monitored.
IQ Card / sensor enrollment
- Match module to panel model — IQ Card SKU must match legacy sensor frequency.
- Install antenna before powering module for first time when manual requires it.
- Run communication test and document ICCID for dealer activation.
Power and connectivity reference
| Product type | Power | Network / RF |
|---|---|---|
| IQ Panel 4/5/Pro/Hub panel | AC + backup battery | PowerG sensors; IQ Cards; Z-Wave automation |
| Wireless sensor | Battery per SKU | PowerG encrypted; IQ Card 319/345 legacy |
| Cell module | Panel-powered | LTE to dealer / Alarm.com |
| IQ Remote keypad | PowerG link | IQ Panel host |
| Z-Wave module | Mains or battery per device | Z-Wave to panel |
Source: IQ Card quick guide for your frequency (Qolsys official documentation).