Interlogix Reed switch recessed, 1/2″ gap, white Installation Notes

Hardwired magnetic contact or reed switch — wired door/window loop for VISTA, Challenger DGP, Reliance, or commercial panel inputs (1035/1045/2200/2500 series, Sentrol reeds). On Interlogix systems, wireless devices...

Overview

Hardwired magnetic contact or reed switch — wired door/window loop for VISTA, Challenger DGP, Reliance, or commercial panel inputs (1035/1045/2200/2500 series, Sentrol reeds).

On Interlogix systems, wireless devices are supervised zones on the panel — tamper, low battery, and missing signals appear as trouble conditions that may block arming depending on panel programming.

At a Glance

SpecificationDetails
DetectionOpen/close magnetic circuit
WiringNormally closed loop with EOL supervision
InstallSurface, recessed, or industrial wide-gap models
UseHardwired panel zones — not TX-E wireless

What This Device Does Well

Provides reliable supervised status at the panel and Alarm.com / UltraSync when installed, enrolled, and range-tested correctly.

Before You Service or Replace One

  • Sensor SKUTX-E wireless vs hardwired loop vs 433 MHz expander path.
  • Panel online — resolve panel AC/comms trouble before blaming sensor.
  • Range433 MHz expander or move wireless receiver for distant zones.
  • Battery type — use listed cell; replace all batteries in multi-cell devices.
  • Tamper — cover fully closed before declaring hardware fault.

Official Sources

Use official Aritech install PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.

Installation Notes

Follow Magnetic contact install datasheet and the official resource links in this product folder for mounting, wiring, and enrollment.

Pre-install checklist

  • Confirm panel model (Simon/Challenger/Reliance/Tecom) and encryption requirements.
  • Verify dealer cell account and module SKU before cell install.
  • Document installer code and existing zone map for takeover jobs.
  • Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
  • Have listed batteries and tools for sensor mounts before enrollment.

Typical install sequence

  1. Mount and power panel; apply firmware updates per dealer bulletin.
  2. Install cell module and run communication test / Alarm.com / UltraSync activation.
  3. Enroll wireless sensors via installer Learn mode; label zones.
  4. Include Z-Wave devices after excluding from any prior hub.
  5. Install 433 MHz expander or optimize receiver placement before fringe wireless sensors.
  6. Run walk test, user code training, and central station test if monitored.

Magnetic contact alignment

  • Gap between sensor and magnet must be within spec — too wide reads open.
  • Use spacers on uneven trim; verify tamper clears when cover closed.
  • For encrypted TX-E sensor, enroll on Simon learn mode support enabled.

Power and connectivity reference

Product typePowerNetwork / RF
Simon/Challenger/Reliance/Tecom panelAC + backup batteryDGP expanders; RAS keypads; 4G/IP communicators
Wireless sensorBattery per SKU319.5 MHz TX-E; 433 MHz on Reliance NXG-433
Cell modulePanel-poweredLTE to dealer / Alarm.com / UltraSync
RAS keypadData busChallenger/Tecom host
Z-Wave moduleMains or battery per deviceZ-Wave to panel

Source: Magnetic contact install datasheet (Aritech official documentation).