Overview
Hardwired initiating device — wired PIR, glass break, or contact for direct connection to VISTA zone inputs (IS335, DT8050, FG1625, etc.).
On Honeywell systems, wireless devices are supervised zones on the panel — tamper, low battery, and missing signals appear as trouble conditions that may block arming depending on panel programming.
At a Glance
| Specification | Details |
|---|---|
| Wiring | Direct to panel zone with EOL supervision |
| Power | Powered or passive per device type |
| Use | VISTA wired zones — not 5800 wireless |
What This Device Does Well
Provides reliable supervised status at the panel and Total Connect 2.0 when installed, enrolled, and range-tested correctly.
Before You Service or Replace One
- Sensor SKU — 5800 Series one-way vs SiX two-way encrypted vs hardwired.
- Panel online — resolve panel AC/cell trouble before blaming sensor.
- Range — 5800RP repeater or move 5881EN/6160RF receiver path for distant zones.
- Battery type — use listed cell; replace all batteries in multi-cell devices.
- Tamper — cover fully closed before declaring hardware fault.
Official Sources
- Resideo product page
- User Manual for 3120B Hardwire Dual Photoelectric and Ionization Sensor Smoke Alarm (English, Spanish)
- 3120B CSFM Listing Card
- 3120B ETL Listing Card
- 3120B Architect and Engineering Specifications
- 3120B Specification Sheet
- More Information on Ionization vs. Photoelectric Smoke Alarms
Use official Resideo install PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.
Installation Notes
Follow Hardwired sensor install guide and the official resource links in this product folder for mounting, wiring, and enrollment.
Pre-install checklist
- Confirm panel model (VISTA/Lynx/ProSeries/Lyric) and encryption requirements.
- Verify dealer cell account and module SKU before cell install.
- Document installer code and existing zone map for takeover jobs.
- Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
- Have listed batteries and tools for sensor mounts before enrollment.
Typical install sequence
- Mount and power panel; apply firmware updates per dealer bulletin.
- Install cell module and run communication test / Total Connect 2.0 activation.
- Enroll wireless sensors via installer Learn mode; label zones.
- Include Z-Wave devices after excluding from any prior hub.
- Install 5800RP repeater or optimize receiver placement before fringe 5800 sensors.
- Run walk test, user code training, and central station test if monitored.
Power and connectivity reference
| Product type | Power | Network / RF |
|---|---|---|
| VISTA/Lynx/ProSeries/Lyric panel | AC + backup battery | 5800 receiver; ECP keypads; AlarmNet LTE/IP |
| Wireless sensor | Battery per SKU | 345 MHz 5800 Series; SiX on ProSeries/Lyric |
| Cell module | Panel-powered | LTE to dealer / Total Connect 2.0 |
| ECP keypad | Panel bus power | ECP to VISTA |
| Z-Wave module | Mains or battery per device | Z-Wave to panel |
Source: Hardwired sensor install guide (Resideo official documentation).