PC6108 adds 8 hardwired zones to classic PowerSeries Keybus panels. Product type Module / accessory At a glance DetailValueCategoryModule / accessoryPrimary manualPC6108 Installation SheetInstall scopePremises panel o...

Overview

PC6108 adds 8 hardwired zones to classic PowerSeries Keybus panels.

Product type

Module / accessory

At a glance

DetailValue
CategoryModule / accessory
Primary manualPC6108 Installation Sheet
Install scopePremises panel or bus device
SupervisionPanel trouble display when faulted

What this device does in the system

Extends panel capacity (zones, outputs, wireless, power, or reporting) — plan bus address, current draw, and device limits before install.

Before you install or replace one

  • Confirm exact model number on the label matches the install manual.
  • Verify host panel or system family — Keybus, Corbus, Combus, PowerG, MX, or 433 MHz are not interchangeable.
  • Check device limits on the panel/receiver before adding zones, sirens, or credentials.
  • Include current draw in power budget calculations for modules, receivers, and keypads.
  • For wireless: test RF at the mounted location, not only on the bench.