2GIG Smoke/Heat/Freeze Sensor (SMKT8) FAQs

2GIG smoke, heat, freeze, or CO detector — life-safety wireless initiating device; requires code-compliant placement and monitoring where applicable. Life-safety devices have stricter placement and testing requireme...

Overview

2GIG smoke, heat, freeze, or CO detector — life-safety wireless initiating device; requires code-compliant placement and monitoring where applicable.

Life-safety devices have stricter placement and testing requirements than burglary sensors. Follow NFPA/local code, use professional monitoring where required, and never substitute takeover modules for fire or CO hardwire.

At a Glance

SpecificationDetails
DetectionSmoke/heat/freeze (SMKT8) or CO (CO8) — SKU specific
Wireless345 MHz; encrypted SMKT8e / CO8e on e panels
Life safetyFollow NFPA/local code; professional monitoring recommended
PowerBattery or listed power — verify model
MaintenanceReplace per manufacturer life; test monthly

What This Device Does Well

Provides reliable supervised status at the panel and Alarm.com when installed, enrolled, and range-tested correctly.

Before You Service or Replace One

  • Device age — smoke/CO sensors expire; replace per label date.
  • Zone type — fire vs burglary programming differs; do not bypass without authority.
  • FireFighter placement — acoustic path to standalone smoke alarms.
  • Monitoring — central station fire test procedures for monitored accounts.

Official Sources

Use official 2GIG PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.

FAQs

Why does my zone show trouble?

Most common: low battery, tamper open, out of range, or wrong sensor type for the panel receiver (345 MHz vs ePlus 900 MHz).

How do I replace a sensor?

Delete old zone in installer programming, enroll replacement using Learn mode, and test walk test at final location.

Will Alarm.com show this device?

When the panel has active interactive service, enrolled zones appear in the Alarm.com app with status matching the panel.

Where is official documentation?

Primary reference: 2GIG smoke/CO device install guide

How do I test after installation?

Use panel walk test, zone status, and (if monitored) central station test per dealer procedure.

Can I mix 345 MHz and ePlus sensors?

ePlus 900 MHz sensors require XCVR2 transceiver hardware — they do not enroll on the standard 345 MHz receiver alone.

Why does my zone show trouble?

Most common: low battery, tamper open, out of range, or wrong sensor type for the panel receiver (345 MHz vs ePlus 900 MHz).

How do I replace a sensor?

Delete old zone in installer programming, enroll replacement using Learn mode, and test walk test at final location.

Will Alarm.com show this device?

When the panel has active interactive service, enrolled zones appear in the Alarm.com app with status matching the panel.

Where is official documentation?
How do I test after installation?

Use panel walk test, zone status, and (if monitored) central station test per dealer procedure.

Can I mix 345 MHz and ePlus sensors?

ePlus 900 MHz sensors require XCVR2 transceiver hardware — they do not enroll on the standard 345 MHz receiver alone.