2GIG E+ Extended Range Outdoor Wireless Contact Sensor Compatible Systems & Integrations

2GIG ePlus extended-range sensor — 900 MHz family for large properties requiring greater RF reach when used with XCVR2 transceiver hardware. On 2GIG systems, wireless devices are supervised zones on the panel — ta...

Overview

2GIG ePlus extended-range sensor — 900 MHz family for large properties requiring greater RF reach when used with XCVR2 transceiver hardware.

On 2GIG systems, wireless devices are supervised zones on the panel — tamper, low battery, and missing signals appear as trouble conditions that may block arming depending on panel programming.

At a Glance

SpecificationDetails
Wireless900 MHz ePlus to XCVR2 transceiver
RangeExtended vs standard 345 MHz — still requires placement test
TypesContact, motion, glass, smoke — ePlus SKU per function
Host requirementPanel + XCVR2 programmed correctly

What This Device Does Well

Provides reliable supervised status at the panel and Alarm.com when installed, enrolled, and range-tested correctly.

Before You Service or Replace One

  • Sensor SKU — standard 345 MHz vs eSeries encrypted vs ePlus 900 MHz.
  • Panel online — resolve panel AC/cell trouble before blaming sensor.
  • Range — repeaters (RPTR1) or transceivers (XCVR2) for distant zones.
  • Battery type — use listed cell; replace all batteries in multi-cell devices.
  • Tamper — cover fully closed before declaring hardware fault.

Official Sources

Use official 2GIG PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.

Compatible Peripherals

This page lists 2GIG ecosystem compatibility — panels, transceivers, repeaters, and monitoring platforms — not third-party panel brands unless using an approved takeover path.

Host compatibility

Host / ecosystemHow it connects
XCVR2 900 MHz transceiverRequired RF host for ePlus sensors
GC2e / GC3e / EdgePanel supervising transceiver

Not compatible / common mistakes

  • ePlus sensors on 345 MHz-only receiver without XCVR2
  • Assuming ePlus replaces repeater needs in all floor plans

Replacement guidance

  • Match SKU and encryption generation on product label before ordering.
  • Delete old zone/device in installer programming before enrolling replacement.
  • Document zone number and name for user and central station records.
  • Run walk test and communication test after swap on monitored accounts.

Source: 2GIG ePlus and XCVR2 install guide (2GIG official documentation).