2GIG Encrypted 4-Button Keyfob Remote (KEY2e) Installation Notes

2GIG hardwire takeover module — converts existing 12 V wired burglary zones to wireless 345 MHz zones on the 2GIG panel (not for fire/CO hardwire). On 2GIG systems, wireless devices are supervised zones on the panel...

Overview

2GIG hardwire takeover module — converts existing 12 V wired burglary zones to wireless 345 MHz zones on the 2GIG panel (not for fire/CO hardwire).

On 2GIG systems, wireless devices are supervised zones on the panel — tamper, low battery, and missing signals appear as trouble conditions that may block arming depending on panel programming.

At a Glance

SpecificationDetails
RoleWired zone takeover to wireless
Input12 V burglary loops — not fire or CO
Wireless345 MHz; encrypted TAKE1e available
IndoorListed for indoor use only

What This Device Does Well

Provides reliable supervised status at the panel and Alarm.com when installed, enrolled, and range-tested correctly.

Before You Service or Replace One

  • Sensor SKU — standard 345 MHz vs eSeries encrypted vs ePlus 900 MHz.
  • Panel online — resolve panel AC/cell trouble before blaming sensor.
  • Range — repeaters (RPTR1) or transceivers (XCVR2) for distant zones.
  • Battery type — use listed cell; replace all batteries in multi-cell devices.
  • Tamper — cover fully closed before declaring hardware fault.

Official Sources

Use official 2GIG PDFs and install guides for exact wiring, enrollment, and firmware — specifications vary by SKU and region.

Installation Notes

Follow 2GIG takeover module install guide and the official resource links in this product folder for mounting, wiring, and enrollment.

Pre-install checklist

  • Confirm panel model (GC2/GC3/Edge) and encryption requirements.
  • Verify dealer cell account and module SKU before cell install.
  • Document installer code and existing zone map for takeover jobs.
  • Plan antenna routing (ANT5XL) when panel location has poor cell RSSI.
  • Have listed batteries and tools for sensor mounts before enrollment.

Typical install sequence

  1. Mount and power panel; apply firmware updates per dealer bulletin.
  2. Install cell module and run communication test / Alarm.com activation.
  3. Enroll wireless sensors via installer Learn mode; label zones.
  4. Include Z-Wave devices after excluding from any prior hub.
  5. Install transceiver/repeater hardware before distant ePlus or fringe sensors.
  6. Run walk test, user code training, and central station test if monitored.

Takeover wiring

  • Burglary loops only — do not wire fire or CO zones to takeover inputs.
  • Verify 12 V loop polarity and end-of-line configuration per module guide.
  • Label wireless zone numbers to match former wired zone map for user clarity.

Power and connectivity reference

Product typePowerNetwork / RF
GC2/GC3/Edge panelAC + backup battery345 MHz receiver; Z-Wave; optional LTE
Wireless sensorBattery per SKU345 MHz; ePlus 900 MHz with XCVR2
Cell modulePanel-poweredLTE to dealer / Alarm.com
GC Touch keypadAC + battery backupWireless to panel
Z-Wave moduleMains or battery per deviceZ-Wave to panel

Source: 2GIG takeover module install guide (2GIG official documentation).